Flow-type magnetic separator MF 65/1-P6-N-4-80-N-P

This separator not suit you?
We will make a custom separator for you
Contact us

Customer support

+1 619 488 1743
info@magneticseparators.us

Make an inquiry

Parameters

Material Stainless steel DIN 1.4301, EN 10088, ČSN 17240, AISI 304, AKV 7 - non-stabilized austenitic nickel-chromium steel (X5CrNi 18-10)
Number of magnetic bars 3
Total weight 39.7 lbs
Magnet temperature resistance 176 °F
Input/output 2.0 in
Body surface finish Glass ball blasting
Sealing Silicone (-58 °F to 302 °F)
Piping connection 2x screwing; DIN 11851 DN 50 PN6; material: 1.4301
Number of casings Single casing
Number of magnetic rods detail 3 (3 x dia. 1.2 in)
Tearing force 106 N
Maximum pressure PS 6 bar
Maximum temperature TS 176 °F
Magnetic component weight 21.6 lbs
Magnetic force 12.200 Gs
Product state New
Design UP
Magnet type Neodymium (NdFeB)
Replaceable tubes ANO
Suitable for food industry YES
52520
8595134062441
$3,166.31 $2,925.00

Supplementary letter

The equipment is designed to separate metallic impurities from media that are not hazardous per Article 13 of Directive 2014/68/EU (PED) - Media group 2. These magnetic flow separators do not fall under any category of pressure equipment per 2014/68/EU (Article 4, para. 3). For more information, visit: www.magneticke-separatory.cz (opens in a new window)

For more information, visit:  www.magnetic-separators.info (opens in a new window)

 TEST METHOD

Magnetic Induction Measurement Procedure

The measurement is performed using a standard gauss meter at the point with the highest design magnetic induction - in the position of the pole pieces, or in the lowest point of the magnetic circuit. The test is repeated 3 times in different locations of the magnetic circuit; then the average magnetic induction is calculated.

Tearing force measurement procedure

This force is measured using a polished steel measurement standard with a diameter of 10 mm and a height of 20 mm. The measurement is performed at the point with the highest design magnetic induction - in the position of the pole pieces, or in the lowest point of the magnetic circuit. The force at which the standard is separated is recorded. The test is repeated 3 times and then the average tearing force is calculated.

For your information, this value is 10 N = approx. 1 kg.

The resulting tearing force depends on a range of factors, e.g. on the dimensions of the measurement standard, the air gap between the standard and the tested magnetic circuit, the measurement standard's surface finish, etc.

8 of other products in the same category: